APPLICATION: MEASURING THE TOTAL VOLUME OF COLD POTABLE WATER PASSING THROUGH THE METER(ALSO SUITABLE FOR PURE WATER). 
  
OPERATING CONDITION: 
*THE MAX.ADMISSIBLE WATER PRESSURE 1.6MPa 
*RESISTING WATER TERPERATURE OF 50℃ 
  
SPECIALITY: 
* LOW START-UP FLOW-RATE 
* INSTALLATION IN ANY POSITION (SUCH AS LEVEL, VERTICAL)  
* POSITIVE ROTATING PISTON TYPE, WITH RELIABLE PERFORMANCE                 
* HIGH ACCURACY 
* BRASS BODY 
* ON REQUEST,THIS SERIES CAN BE EQUIPPED WITH THE PULSE DEVICE
  
 Maximum permissible error: 
Between qt (included) and qs is ±2%; 
Between qmin and qt (excluded) is ±5%. 
NOTE: The technical data conform to ISO4064 standard, class C. 
  
FLOW-ERROR CURVE
  
  
 SPECIFICATION AND OVERAL DIMENSIONS
  
| 
 Description  | 
 Unit  | 
 Hydraulic data and dimensions  |  
| 
 Nominal Size  | 
 Mm(inches)  | 
 DN15( 1/2″)  | 
 DN20( 3/4″)  | 
 DN25 (1″)  |  
| 
 Overload flow-rate (qs)  | 
 IMP.GAL/h  | 
 792  | 
 1320  | 
 1848  |  
| 
 Permanent flow-rate (qp)  | 
 IMP.GAL/h  | 
 396  | 
 660  | 
 924  |  
| 
 Transitional flow-rate (qt)  | 
 IMP.GAL/h  | 
 5.94  | 
 9.9  | 
 13.86  |  
| 
 Minimum flow-rate (qmin)  | 
 IMP.GAL/h  | 
 3.96  | 
 6.6  | 
 9.24  |  
| 
 Min. Reading  | 
 IMP.Gallons  | 
 0.05  | 
 0.05  | 
 0.05  |  
| 
 Max. Reading  | 
 IMP.Gallons  | 
 9999999.9  | 
 9999999.9  | 
 9999999.9  |  
| 
 Max. working pressure  | 
 MPa  | 
 1.6  | 
 1.6  | 
 1.6  |  
| 
 △P at the qs  | 
 MPa  | 
 ≤0.1  | 
 ≤0.1  | 
 ≤0.1  |  
| 
 L  | 
 mm  | 
 195  | 
 267  | 
 319  |  
| 
 I  | 
 mm  | 
 115  | 
 165  | 
 199   |  
| 
 B  | 
 mm  | 
 43  | 
 43  | 
 53  |  
| 
 Weight  | 
 With connections  | 
 Kg  | 
 1.14  | 
 1.56  | 
 2.48  |  
| 
 Without connections   | 
 0.97  | 
 1.3  | 
 2.05  |    OVERALL DIMENSIONS    PRESSURE LOSS CURVE
   |